[email protected]   +86 183 2145 9135 Inquiry Now
** This session may be vulnerable to "store now, decrypt later" attacks. ** The server may need to be upgraded. See https://openssh.com/pq.html
Home › Products › Pulsed-Vacuum VHP Generator
VHP Sterilization
FG-VHP-G

Pulsed-Vacuum VHP Generator

Combines vaporized hydrogen peroxide (VHP) technology with pulsed-vacuum pressure control, cycling evacuation and pressure restoration to help drive VHP vapor into difficult-to-reach internal areas of complex equipment such as lyophilizers and fermenters without SIP capability.

Request a Quote All Products
Fenggu Pulsed-Vacuum VHP Generator FG-VHP-G

Overview

The Pulsed-Vacuum VHP Generator combines vaporized hydrogen peroxide (VHP) with repeated evacuation and pressure restoration to treat complex equipment interiors, including lyophilizers, fermenters and other equipment without sterilization-in-place (SIP) capability. Cyclic changes in chamber pressure help distribute hydrogen peroxide vapor into recessed areas and complex internal passages. Flash vaporization converts a 30–35% hydrogen peroxide solution into vapor; its oxidative action damages microbial cellular components, including proteins and DNA, providing broad-spectrum antimicrobial activity at ambient temperature. The unit is intended for internal treatment of lyophilizers, fermenters and other complex equipment without SIP capability, and its mobile design supports straightforward operation and positioning.

Biodecontamination Process

  1. Preparation and vacuum pulsing — evacuate the target chamber, then introduce VHP through the sterile-filtered supply path to partially restore pressure; repeat evacuation and pressure restoration to drive vapor into the chamber, connected piping and areas with limited airflow
  2. Injection and vaporization — reduced pressure lowers the liquid boiling point, allowing rapid vaporization at ambient temperature or with mild heating
  3. Distribution and biodecontamination — vacuum and pressure pulses help distribute VHP into recessed areas and across exposed surfaces; oxidative action damages microbial membranes, proteins and DNA
  4. Aeration and drying — after treatment, evacuate the chamber and introduce sterile air; repeat the evacuation and pressure-restoration sequence to remove residual hydrogen peroxide

Key Features

  • Compact enclosure; stainless-steel piping can connect the generator to the equipment being treated
  • Dry VHP biodecontamination process
  • Short treatment cycles with broad-spectrum microbial inactivation
  • Low-temperature process, with a stated temperature range of 4–80°C
  • Hydrogen peroxide breaks down into water and oxygen without toxic decomposition products
  • Low hydrogen peroxide consumption, approximately 5–10 g/m³
  • Cycle efficacy can be verified using biological indicators
  • Automatic treatment cycle after setup and loading

Technical Specifications

External dimensions (L×W×H)600×600×1,000 mmCycle temperature25–35°C
Cycle humidity50–60%Full cycle timeTo be confirmed for the approved cycle
Treatment timeTo be confirmed for the approved cycleVHP concentration150–200 ppm
Residual VHP after aeration≤1 ppmExterior / piping materialSUS304 / SUS316L
Noise level≤50 dB(A)Sporicidal efficacy≥6-log reduction (subject to validation)
Power supply220 V AC / 50 HzSterilant35% food-grade hydrogen peroxide solution
Full cycle time and treatment time depend on the approved, validated cycle for the specific load; confirm with Fenggu engineering before citing these figures in a validation document.

Applications

Lyophilizer interior biodecontaminationFermenter interior biodecontaminationEquipment without SIP capabilityStructurally complex equipment interiors

Request a datasheet or quotation

Tell us your treatment volume and process requirements, and our engineers will recommend the right configuration.

Contact Our Team

Frequently Asked Questions

What is a pulsed-vacuum VHP generator?
A VHP generator that combines vaporized hydrogen peroxide with pulsed-vacuum pressure control, repeatedly cycling chamber pressure to evacuate trapped air and drive vapor into hard-to-reach internal areas, improving penetration over static diffusion.
When should I choose pulsed-vacuum over a standard generator?
For complex or enclosed loads with narrow lumens, blind spaces or long ducting, where deep, uniform penetration matters. For simpler enclosures, a recirculating generator is usually sufficient.
What are the cycle parameters?
Full cycle under 120 minutes, aeration up to 2.5 hours, VHP 150-200 ppm, 1 ppm or less residual, at 25-35 C and 50-60% humidity. Designed for a 6-log or greater reduction (subject to validation).
How quiet and how large is it?
Noise is 50 dB(A) or less, suitable for occupied facilities, in a 600 x 600 x 1000 mm cabinet, SUS304 / SUS316L construction, 220 V AC / 50 Hz, using 35% food-grade H2O2.
What efficacy can we expect?
It is designed for a 6-log or greater sporicidal reduction, confirmed by biological indicators and established by your project validation protocol.
Scroll to Top