[email protected]   +86 183 2145 9135EN|РУ|中文Inquiry Now
HomeProducts › Airlock VHP Sterilization
VHP Sterilization FG-VHP-AL250

Airlock VHP Sterilization

An airlock / buffer room with an integrated vaporized hydrogen peroxide generator that bio-decontaminates the outer surfaces of materials before they enter a Grade A/B critical zone.

Request a Quote All Products
Fenggu Airlock VHP Sterilization FG-VHP-AL250
Fenggu Airlock VHP Sterilization FG-VHP-AL250
Fenggu Airlock VHP Sterilization FG-VHP-AL250
Fenggu Airlock VHP Sterilization FG-VHP-AL250

Overview

The Fenggu Airlock VHP Sterilization system integrates a vaporized hydrogen peroxide (VHP) generator into an airlock / pass-through buffer room, delivering H2O2 gas into the room to bio-decontaminate the outer surfaces of materials before they move from an unclassified or low-grade area into a Grade A/B critical zone. It is used for the clean, dry items that must be transferred in aseptic production — outer packaging of packaging materials, instruments, raw- and auxiliary-material packaging, accessories and environmental-monitoring equipment. The cycle runs automatically in four stages — temperature / humidity pre-conditioning, conditioning, sterilization and aeration — reducing residual VHP to ≤ 1 ppm before the room is opened.

Key Features

  • VHP generator integrated into an airlock / buffer room; also functions as a normal pass-through room
  • Four automatic stages: pre-conditioning (≥ 28 °C, < 30% RH) / conditioning / sterilization / aeration
  • Full SUS304 construction with bio-airtight interlocked doors — both sides cannot open simultaneously
  • Inlet and outlet air pass through H14 HEPA filters to protect the materials
  • Real-time monitoring of temperature, humidity, pressure and H2O2 concentration
  • Siemens PLC control with real-time printing; BMS control when not in a sterilization cycle
  • 6-log sporicidal decontamination; residual VHP reduced to ≤ 1 ppm before opening

Technical Specifications

Process temperature25–35 °CProcess humidity40–60% RH
VHP concentration300–400 ppmResidual VHP after aeration≤ 1 ppm
Bio-decontamination cycle30 minAeration time≤ 1 h
Sporicidal efficacy≥6-log reduction (subject to validation)Noise≤ 75 dB
Exterior materialSUS304Internal pipingSUS316L
Air filtrationH14 HEPAControlSiemens PLC, BMS-linked
Room dimensions and door configuration are built to the buffer-room layout and the classifications of the connected areas. Concentration is held through a low-speed dosing stage to maintain the level required for decontamination.

Applications

Material Airlock Decontamination Buffer-Room VHP Pass-Through Entry to Grade A/B Zones Sterile Material Transfer Packaging & Instrument Decontamination

Request a datasheet or quotation

Tell us the buffer-room size, the connected cleanroom classifications and material types, and our engineers will recommend a suitable airlock VHP configuration.

Contact Our Team

Frequently Asked Questions

What is airlock VHP sterilization?
It integrates a VHP generator into an airlock or buffer room so hydrogen peroxide vapor decontaminates the outer surfaces of materials before they move from an unclassified or low-grade area into a Grade A/B zone, an alternative to a VHP pass box for bulky or heavy loads.
What is the cycle and efficacy?
Process 25-35 C, 40-60% RH, VHP 300-400 ppm; a roughly 30-minute cycle followed by aeration of 1 hour or less to a residual of 1 ppm or less. Designed for a 6-log or greater reduction (subject to validation).
How does it integrate with our facility controls?
Siemens PLC control, linkable to the building management system (BMS). Room size and door configuration are built to your buffer-room layout and the grades of the connected rooms.
What materials and filtration are used?
SUS304 exterior, SUS316L internal piping, H14 HEPA supply and exhaust; noise 75 dB or less.
Scroll to Top