[email protected]   +86 183 2145 9135 Запросить информацию сейчас

Камеры для стерилизации одежды и капюшона: дезинфекция VHP для комбинезонов и капюшона с положительным давлением

VHP Sterilization · Garment & Hood Decon

Garment & Hood Sterilization Chambers: VHP Decontamination for Positive-Pressure Suits & Hoods

По материалам Fenggu Medical Equipment · Физиологическая стерилизация и контроль загрязнения

In BSL-3/4 labs and sterile or containment operations, staff wear positive-pressure hoods, powered air suits and isolation gowns. These are reusable, and their surfaces pick up pathogens or potent material — so they must be decontaminated before reuse. But they carry blowers, HEPA filters and visors, so they cannot be steam-, heat- or wet-cleaned. A garment sterilization chamber — также называемый a hood sterilization chamber, VHP garment decontamination chamber or hydrogen peroxide fumigation chamber — uses vaporized hydrogen peroxide (VHP) to decontaminate the surfaces of hoods and suits at low temperature, residue-free and validatable. This guide explains what it is, why VHP fits, and how the chamber, pass box and cabinet forms compare.

Positive-pressure hood / suit VHP generator H₂O₂ conc. + alarm Sealed door 316L chamber
Garment sterilization chamber: a 316L chamber with the hood/suit hung inside, sealed, VHP-cycled, with concentration display and alarm.

Why positive-pressure hoods and gowns need dedicated decontamination

In high-containment labs and sealed aseptic work, the positive-pressure hoods, air suits and isolation gowns operators wear are directly exposed to environments carrying pathogens or potent dust. They are not disposable — each use, the outer surface may be contaminated, and reusing or handing them over without full decontamination passes the risk straight to the next person. Yet these are delicate: built-in blower, HEPA filter, clear visor, seams and zips mean no steam, no dry heat, no soaking. That calls for a low-temperature, dry, penetrating decontamination that leaves no residue.

Why VHP, not formaldehyde or spray

Vaporized hydrogen peroxide (VHP) fits garment and hood decontamination:

  • Low-temperature and dry. Runs near ambient — no harm to the blower, filter or visor, and nothing gets soaked.
  • Penetrating. The gas reaches zips, seams, filter media and folds — where wiping and spraying cannot.
  • Residue-free and validatable. Breaks down to water and oxygen, no residue; a ≥6-log kill can be proven with biological indicators. See Что такое дезактивация VHP.

By comparison, formaldehyde fumigation leaves residue, needs neutralizing and takes long; alcohol/disinfectant spray only acts on the surface, misses crevices and cannot be validated. So BSL labs and aseptic plants increasingly move to a VHP fumigation chamber for hoods and gowns.

How a garment sterilization chamber is configured

Элемент Деталь
Камера 316L / 304 stainless with internal hangers to suspend hoods and gowns so surfaces are fully exposed to the gas.
Sealed door Inflatable or mechanical-compression door, gastight during the cycle; a two-door version is a garment decontamination pass box separating clean/dirty sides.
VHP generation Integrated VHP generator: inject and circulate, hold concentration, then aerate and catalytically break down.
Безопасность H₂O₂ concentration display and alarm, status lights, interlock; door opens only after residual aerates to a safe level (commonly ≤1 ppm).
Validation Biological indicators mapped to prove a 6-log kill — see Параметры цикла VHP.
Также известный как Garment sterilization chamber, hood sterilization chamber, PPE VHP pass box, hydrogen peroxide garment fumigation chamber, gown decontamination cabinet.

Chamber, pass box or cabinet: which form

The same “seal + VHP” logic, in the form that fits the use:

In a BSL-3/4 containment suite these units join the gastight doors and pass boxes that form the sealed boundary — see Biosafety Airtight Doors for BSL-3/BSL-4 Containment.

Fenggu VHP pass box, same sealed-chamber plus integrated-VHP construction as a garment/hood chamber
A Fenggu VHP pass box — a garment/hood sterilization chamber uses the same sealed-chamber + integrated-VHP construction, configured to hang hoods and gowns.

Часто задаваемые вопросы

Can a positive-pressure hood go through VHP repeatedly — will it damage the gear?
VHP is a low-temperature, dry decontamination compatible with stainless, visors and most suit materials, so it can be used repeatedly; follow the garment maker’s material-compatibility guidance for frequency.

How is this different from an ordinary pass box?
An ordinary pass box only transfers material; a garment sterilization chamber / pass box integrates VHP and is built to hang and decontaminate hoods and gowns to a validated kill.

How soon can items be used after a cycle?
The cycle ends with aeration and catalytic breakdown to a safe residual (commonly ≤1 ppm) before the door opens; the time depends on chamber size and ventilation.

Need validated decontamination for positive-pressure hoods or gowns?

Tell us your hood/gown type, throughput and whether you need cross-wall transfer, and Fenggu will configure a garment sterilization chamber or pass box — integrated VHP, sealed door, concentration alarm and validation as one.

View VHP Pass Boxes
Поговорите с инженером

Вернуться к началу страницы
Получить расценки