{"id":321,"date":"2026-09-03T03:05:06","date_gmt":"2026-09-03T03:05:06","guid":{"rendered":"https:\/\/fenggu-bio.com\/hvac-integrated-vhp-sterilization-saudi-arabia\/"},"modified":"2026-09-04T07:09:02","modified_gmt":"2026-09-04T07:09:02","slug":"hvac-integrated-vhp-sterilization-saudi-arabia","status":"publish","type":"post","link":"https:\/\/fenggu-bio.com\/pt\/hvac-integrated-vhp-sterilization-saudi-arabia\/","title":{"rendered":"Sistema de Esteriliza\u00e7\u00e3o VHP Integrado no Sistema de Climatiza\u00e7\u00e3o \u2013 Solu\u00e7\u00e3o T\u00e9cnica (Ar\u00e1bia Saudita)"},"content":{"rendered":"<style>\n.entry-title,.ast-single-post .entry-header{display:none!important}\n.fg-art{font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,\"Helvetica Neue\",Arial,sans-serif;color:#1e2838;line-height:1.72;max-width:860px;margin:0 auto;padding:0 22px;font-size:16.5px}\n.fg-art .fg-eyebrow{display:inline-block;background:#e3ecfa;color:#003AA1;font-weight:700;font-size:12px;letter-spacing:.7px;padding:5px 13px;border-radius:20px;text-transform:uppercase;margin:34px 0 14px}\n.fg-art h1{font-size:32px;line-height:1.2;color:#002B78;margin:0 0 12px;font-weight:800}\n.fg-art .meta{font-size:13.5px;color:#7a8699;margin:0 0 24px;border-bottom:1px solid #e6ebf3;padding-bottom:16px}\n.fg-art h2{font-size:22px;color:#002B78;margin:40px 0 12px;line-height:1.3;scroll-margin-top:80px;padding-top:6px;border-top:2px solid #eef2f8}\n.fg-art h3{font-size:17.5px;color:#00347a;margin:22px 0 8px}\n.fg-art p{margin:0 0 15px}\n.fg-art .lead{font-size:18px;color:#3a4658}\n.fg-art figure{margin:24px 0}\n.fg-art img{width:100%;border-radius:12px;box-shadow:0 6px 22px rgba(0,58,161,.12);display:block}\n.fg-art figcaption{font-size:13px;color:#7a8699;margin-top:9px;text-align:center}\n.fg-art table{border-collapse:collapse;width:100%;margin:20px 0;font-size:14px}\n.fg-art th,.fg-art td{border:1px solid #d7dfea;padding:9px 12px;text-align:left;vertical-align:top}\n.fg-art thead th{background:#002B78;color:#fff;font-weight:700;text-align:left}\n.fg-art tbody tr:nth-child(even) td{background:#f7f9fc}\n.fg-art ul,.fg-art ol{margin:0 0 15px;padding-left:22px}.fg-art li{margin:6px 0}\n.fg-toc{background:#f4f7fc;border:1px solid #dce5f2;border-radius:12px;padding:20px 24px;margin:26px 0 8px}\n.fg-toc h4{margin:0 0 12px;font-size:14px;letter-spacing:.5px;text-transform:uppercase;color:#003AA1}\n.fg-toc ol{margin:0;padding-left:20px;columns:2;column-gap:34px}\n.fg-toc li{margin:5px 0}.fg-toc a{color:#1e2838;text-decoration:none;font-size:14.5px}.fg-toc a:hover{color:#003AA1;text-decoration:underline}\n.fg-art .fg-cta{background:linear-gradient(120deg,#002B78,#003AA1);color:#fff;border-radius:14px;padding:30px 28px;margin:40px 0 10px;text-align:center}\n.fg-art .fg-cta h3{color:#fff;font-size:22px;margin:0 0 8px}\n.fg-art .fg-cta p{color:#dce7f7;margin:0 0 18px;font-size:15.5px}\n.fg-art .fg-btn{display:inline-block;background:#EC001B;color:#fff;padding:13px 28px;border-radius:6px;font-weight:600;font-size:15.5px;text-decoration:none;margin:0 6px 8px}\n.fg-art .fg-btn.o{background:transparent;border:2px solid rgba(255,255,255,.7)}\n.fg-art a{color:#003AA1;text-decoration:underline}\n.fg-art .fg-cta a,.fg-toc a{text-decoration:none}.fg-art .fg-cta a{color:#fff}\n@media(max-width:640px){.fg-art h1{font-size:25px}.fg-toc ol{columns:1}.fg-art th,.fg-art td{padding:8px 9px;font-size:13px}}\n<\/style>\n<article class=\"fg-art\">\n<span class=\"fg-eyebrow\">Caso de projeto \u00b7 Ar\u00e1bia Saudita<\/span><\/p>\n<h1>Sistema de esteriliza\u00e7\u00e3o VHP integrado ao sistema de climatiza\u00e7\u00e3o \u2014 Solu\u00e7\u00e3o t\u00e9cnica<\/h1>\n<div class=\"meta\">Da Fenggu Medical Equipment \u00b7 Isolamento e conten\u00e7\u00e3o farmac\u00eauticos \u00b7 FGVHP-1000<\/div>\n<figure>\n<img width=\"801\" height=\"1068\" decoding=\"async\" src=\"\/wp-content\/uploads\/site\/ksa-vhp-install-1.jpg\" alt=\"Sistema de esteriliza\u00e7\u00e3o VHP Fenggu FGVHP-1000 integrado ao sistema de climatiza\u00e7\u00e3o, instalado e ligado \u00e0 rede de condutas de climatiza\u00e7\u00e3o\"><figcaption>O Fenggu FGVHP-1000 instalado na sala de equipamentos e ligado \u00e0 rede de condutas do sistema de climatiza\u00e7\u00e3o para esteriliza\u00e7\u00e3o VHP em tempo real.<\/figcaption><\/figure>\n<p class=\"lead\">Uma solu\u00e7\u00e3o t\u00e9cnica concebida para uma unidade farmac\u00eautica na Ar\u00e1bia Saudita: um sistema de esteriliza\u00e7\u00e3o por per\u00f3xido de hidrog\u00e9nio vaporizado (VHP) integrado no sistema de climatiza\u00e7\u00e3o (HVAC), que permite a biodecontamina\u00e7\u00e3o sem supervis\u00e3o e sem zonas mortas de duas \u00e1reas est\u00e9reis atrav\u00e9s de uma \u00fanica unidade FGVHP-1000, integrada diretamente nas unidades de tratamento de ar do sistema de climatiza\u00e7\u00e3o existentes.<\/p>\n<div class=\"fg-toc\">\n<h4>\u00cdndice<\/h4>\n<ol>\n<li><a href=\"#s1\">Vis\u00e3o geral da proposta de projeto<\/a><\/li>\n<li><a href=\"#s2\">Princ\u00edpio da esteriliza\u00e7\u00e3o<\/a><\/li>\n<li><a href=\"#s3\">Descri\u00e7\u00e3o do processo de esteriliza\u00e7\u00e3o<\/a><\/li>\n<li><a href=\"#s4\">Especifica\u00e7\u00f5es T\u00e9cnicas<\/a><\/li>\n<li><a href=\"#s5\">Lista de Configura\u00e7\u00f5es do Sistema<\/a><\/li>\n<li><a href=\"#s6\">Sistema de circula\u00e7\u00e3o por condutas<\/a><\/li>\n<li><a href=\"#s7\">\u00c2mbito do fornecimento<\/a><\/li>\n<li><a href=\"#s8\">Documenta\u00e7\u00e3o (Sistema de ficheiros)<\/a><\/li>\n<li><a href=\"#s9\">Notas importantes<\/a><\/li>\n<li><a href=\"#s10\">Anexo: VHP integrado vs. VHP m\u00f3vel<\/a><\/li>\n<\/ol>\n<\/div>\n<h2 id=\"s1\">I. Vis\u00e3o geral da proposta de projeto<\/h2>\n<p>O Sistema Integrado de Esteriliza\u00e7\u00e3o com Per\u00f3xido de Hidrog\u00e9nio da Shanghai Fenggu Pharmaceutical Equipment Co., Ltd. \u00e9 uma solu\u00e7\u00e3o profissional de esteriliza\u00e7\u00e3o que integra perfeitamente o equipamento de esteriliza\u00e7\u00e3o com per\u00f3xido de hidrog\u00e9nio nos sistemas de climatiza\u00e7\u00e3o (HVAC) existentes. Aproveitando o sistema de circula\u00e7\u00e3o de ar do sistema de climatiza\u00e7\u00e3o, este sistema distribui uniformemente per\u00f3xido de hidrog\u00e9nio vaporizado (VHP) por todos os espa\u00e7os que requerem esteriliza\u00e7\u00e3o e pela rede de condutas do sistema de climatiza\u00e7\u00e3o, permitindo opera\u00e7\u00f5es de esteriliza\u00e7\u00e3o sem supervis\u00e3o. Garante uma esteriliza\u00e7\u00e3o completa, sem quaisquer zonas mortas nas \u00e1reas est\u00e9reis, nas condutas de alimenta\u00e7\u00e3o e de exaust\u00e3o do sistema AVAC e na sec\u00e7\u00e3o a montante dos filtros HEPA. O forte poder oxidante do per\u00f3xido de hidrog\u00e9nio rompe as membranas celulares e as estruturas proteicas e de \u00e1cidos nucleicos dos microrganismos, alcan\u00e7ando uma efic\u00e1cia de esteriliza\u00e7\u00e3o de amplo espectro de 99,9999% (n\u00edvel Log6) contra bact\u00e9rias, v\u00edrus, esporos e outros agentes patog\u00e9nicos. O per\u00f3xido de hidrog\u00e9nio residual ap\u00f3s a esteriliza\u00e7\u00e3o decomp\u00f5e-se em \u00e1gua e oxig\u00e9nio, sem produzir subprodutos t\u00f3xicos. Este sistema \u00e9 particularmente adequado para salas de prepara\u00e7\u00e3o est\u00e9ril, instala\u00e7\u00f5es de fabrico biofarmac\u00eautico, laborat\u00f3rios P2 e P3 e ambientes semelhantes.<\/p>\n<p>Este equipamento \u00e9 composto por um desumidificador rotativo, um filtro de alta efici\u00eancia, um ventilador de alta press\u00e3o, tubagem em CPVC, uma unidade de evapora\u00e7\u00e3o VHP e outros componentes; todos os seus componentes principais s\u00e3o fabricados por marcas de renome internacional. Atualmente, a Shanghai Fenggu Pharmaceutical Equipment Co., Ltd. disponibiliza tr\u00eas modelos padr\u00e3o \u2014 FGVHP1000 metros c\u00fabicos, FGVHP2000 metros c\u00fabicos e FGVHP3000 metros c\u00fabicos \u2014 \u00e0 escolha dos clientes; tamb\u00e9m podem ser fornecidos modelos personalizados com volumes de esteriliza\u00e7\u00e3o maiores, quando necess\u00e1rio.<\/p>\n<p>De acordo com os requisitos do utilizador, a \u00e1rea de desinfe\u00e7\u00e3o corresponde a dois sistemas de ar condicionado \u2014 as unidades AHU-S05 e AHU-S06 \u2014, sendo os volumes das salas est\u00e9ril 362 metros c\u00fabicos e 418 metros c\u00fabicos, respetivamente. Durante a esteriliza\u00e7\u00e3o, o volume das condutas de retorno de ar do sistema de climatiza\u00e7\u00e3o tamb\u00e9m deve ser tido em conta; por conseguinte, o volume real de esteriliza\u00e7\u00e3o ser\u00e1 maior. Uma vez que as unidades AHU-S05 e AHU-S06 se encontram relativamente pr\u00f3ximas uma da outra, de acordo com a planta de disposi\u00e7\u00e3o do processo, recomenda-se a instala\u00e7\u00e3o de um \u00fanico dispositivo FGVHP-1000 para realizar a esteriliza\u00e7\u00e3o online com VHP em ambos os espa\u00e7os. A capacidade m\u00e1xima de esteriliza\u00e7\u00e3o de uma \u00fanica unidade FGVHP-1000 \u00e9 de 1 000 metros c\u00fabicos. O diagrama esquem\u00e1tico detalhado desta solu\u00e7\u00e3o \u00e9 apresentado abaixo:<\/p>\n<figure>\n<img width=\"991\" height=\"701\" decoding=\"async\" src=\"\/wp-content\/uploads\/site\/fgvhp1000-schematic.jpg\" alt=\"Esquema do gerador VHP FGVHP-1000 ligado, atrav\u00e9s de tubagem em CPVC e v\u00e1lvulas de controlo, aos condutos de alimenta\u00e7\u00e3o das unidades AHU-S05 e AHU-S06\"><figcaption>Esquema da solu\u00e7\u00e3o: desumidificador de roda rotativa \u2192 filtro H14 \u2192 gerador FGVHP-1000, dosagem de per\u00f3xido de hidrog\u00e9nio 35%, fornecimento de VHP atrav\u00e9s das v\u00e1lvulas A1\/A2 para os condutos de alimenta\u00e7\u00e3o das unidades AHU-S05 e AHU-S06.<\/figcaption><\/figure>\n<p>Com base nos par\u00e2metros acima referidos e na planta, a Shanghai Fenggu Pharmaceutical Equipment Co., Ltd. prop\u00f5e o seguinte conceito de projeto:<\/p>\n<ul>\n<li>Conceber e instalar um \u00fanico gerador FGVHP-1000;<\/li>\n<li>S\u00e3o utilizadas duas condutas de CPVC para ligar a unidade geradora de VHP \u00e0s condutas de ar de alimenta\u00e7\u00e3o dos sistemas de ar condicionado AHU-S05 e AHU-S06, respetivamente;<\/li>\n<li>Integra\u00e7\u00e3o do gerador de VHP com o sistema de climatiza\u00e7\u00e3o para a esteriliza\u00e7\u00e3o c\u00edclica da \u00e1rea est\u00e9ril;<\/li>\n<li>Efetuar a esteriliza\u00e7\u00e3o da \u00e1rea atrav\u00e9s do controlo das v\u00e1lvulas na conduta de distribui\u00e7\u00e3o;<\/li>\n<li>O sistema pode realizar uma purifica\u00e7\u00e3o cont\u00ednua durante a noite; ao mudar da esteriliza\u00e7\u00e3o AHU-S05 para a esteriliza\u00e7\u00e3o AHU-S06, n\u00e3o \u00e9 necess\u00e1ria qualquer interven\u00e7\u00e3o manual \u2014 o sistema gere automaticamente a transi\u00e7\u00e3o entre as zonas de esteriliza\u00e7\u00e3o, e n\u00e3o \u00e9 permitida a presen\u00e7a de pessoal na \u00e1rea limpa durante o processo de esteriliza\u00e7\u00e3o.<\/li>\n<\/ul>\n<p>Dura\u00e7\u00e3o do ciclo de esteriliza\u00e7\u00e3o: aproximadamente 120 minutos; tempo de aera\u00e7\u00e3o e remo\u00e7\u00e3o de res\u00edduos: 1 a 2 horas. Se a taxa de ventila\u00e7\u00e3o de exaust\u00e3o for inferior a 15 vezes por hora, a dura\u00e7\u00e3o da aera\u00e7\u00e3o deve ser aumentada.<\/p>\n<figure>\n<img width=\"939\" height=\"659\" decoding=\"async\" src=\"\/wp-content\/uploads\/site\/hvac-integrated-vhp-layout.jpg\" alt=\"Planta em 3D do sistema VHP integrado ao sistema de climatiza\u00e7\u00e3o, mostrando as condutas de ar de alimenta\u00e7\u00e3o e de retorno e o gerador VHP\"><figcaption>Como o sistema se integra ao sistema de climatiza\u00e7\u00e3o da sala: o VHP \u00e9 injetado no ar de alimenta\u00e7\u00e3o e circula pela \u00e1rea est\u00e9ril e pela rede de condutas.<\/figcaption><\/figure>\n<h2 id=\"s2\">II. Princ\u00edpio da esteriliza\u00e7\u00e3o<\/h2>\n<p>O Sistema de Esteriliza\u00e7\u00e3o FGVHP-1000 tira partido da efic\u00e1cia esporicida superior do per\u00f3xido de hidrog\u00e9nio na forma gasosa \u00e0 temperatura ambiente, em compara\u00e7\u00e3o com a sua forma l\u00edquida \u2014 atrav\u00e9s da gera\u00e7\u00e3o de radicais hidroxilo livres que atuam sobre os componentes celulares \u2014 incluindo l\u00edpidos, prote\u00ednas e ADN \u2014 para alcan\u00e7ar uma esteriliza\u00e7\u00e3o completa. Este sistema \u00e9 um equipamento especialmente concebido para a esteriliza\u00e7\u00e3o a baixa temperatura em \u00e1reas limpas.<\/p>\n<p>A esteriliza\u00e7\u00e3o com VHP \u00e9 um m\u00e9todo de esteriliza\u00e7\u00e3o com g\u00e1s seco; o VHP ativo n\u00e3o se condensa em nenhuma superf\u00edcie dentro da sala limpa, evitando assim danos por corros\u00e3o na maioria dos materiais.<\/p>\n<h2 id=\"s3\">III. Descri\u00e7\u00e3o do processo de esteriliza\u00e7\u00e3o<\/h2>\n<p>Durante o funcionamento do FGVHP-1000, o ciclo de esteriliza\u00e7\u00e3o consiste em quatro fases distintas:<\/p>\n<h3>1. Fase de desumidifica\u00e7\u00e3o<\/h3>\n<p>A humidade na \u00e1rea limpa \u00e9 mantida abaixo de 50% e a temperatura \u00e9 mantida acima dos 25 \u00b0C atrav\u00e9s dos sistemas de \u00e1gua fria e quente integrados na unidade; este processo determina diretamente a efic\u00e1cia da esteriliza\u00e7\u00e3o. Durante esta fase, o gerador de VHP pr\u00e9-aquece primeiro o fluxo na conduta de inje\u00e7\u00e3o de VHP para que este sirva de ve\u00edculo para o vapor de per\u00f3xido de hidrog\u00e9nio; durante a fase de biodecontamina\u00e7\u00e3o, a concentra\u00e7\u00e3o do vapor de per\u00f3xido de hidrog\u00e9nio pode ser mantida abaixo do n\u00edvel de satura\u00e7\u00e3o (ponto de orvalho). Normalmente, o caudal m\u00e1ximo de ar atrav\u00e9s do sistema de biodecontamina\u00e7\u00e3o FGVHP-1000 \u00e9 de 300 m\u00b3\/h; este caudal de ar \u00e9 tamb\u00e9m influenciado pela velocidade do ventilador do gerador de VHP e pelas limita\u00e7\u00f5es impostas pelo sistema de tubagem externo.<\/p>\n<p><em>Nota: O tempo necess\u00e1rio para atingir a humidade e a temperatura pretendidas depende tamb\u00e9m da humidade, da temperatura e do volume iniciais da divis\u00e3o.<\/em><\/p>\n<h3>2. Fase de condicionamento<\/h3>\n<p>O processo de aumento cont\u00ednuo da concentra\u00e7\u00e3o de VHP; durante este processo, o vapor de VHP \u00e9 injetado continuamente na rede de condutas do sistema de climatiza\u00e7\u00e3o. Durante a fase de condicionamento, a taxa de inje\u00e7\u00e3o do esterilizante de per\u00f3xido de hidrog\u00e9nio \u00e9 mantida dentro do intervalo de 50\u201390 g\/min, dependendo do volume da \u00e1rea de esteriliza\u00e7\u00e3o necess\u00e1ria, para atingir a concentra\u00e7\u00e3o alvo de biodecontamina\u00e7\u00e3o. O tempo de condicionamento \u00e9 influenciado por fatores como a taxa de inje\u00e7\u00e3o do esterilizante \u00e0 base de per\u00f3xido de hidrog\u00e9nio, o volume da \u00e1rea limpa e a temperatura.<\/p>\n<h3>3. Fase de biodecontamina\u00e7\u00e3o<\/h3>\n<p>Durante este processo, ao manter uma baixa taxa de inje\u00e7\u00e3o de per\u00f3xido de hidrog\u00e9nio, a concentra\u00e7\u00e3o de vapor de per\u00f3xido de hidrog\u00e9nio no interior da sala pode ser mantida a um n\u00edvel relativamente est\u00e1vel, permitindo a biodecontamina\u00e7\u00e3o. Durante o processo de biodecontamina\u00e7\u00e3o, a concentra\u00e7\u00e3o do g\u00e1s na zona de biodecontamina\u00e7\u00e3o \u00e9 distribu\u00edda uniformemente. Durante a fase de biodecontamina\u00e7\u00e3o, as unidades de refrigera\u00e7\u00e3o e aquecimento do sistema de climatiza\u00e7\u00e3o s\u00e3o desligadas. Condi\u00e7\u00f5es de biodecontamina\u00e7\u00e3o: 25\u201330 \u00b0C, 30\u201350% de humidade relativa. A zona de biodecontamina\u00e7\u00e3o \u00e9 controlada atrav\u00e9s do funcionamento da v\u00e1lvula de controlo das \u00e1reas de entrada\/sa\u00edda.<\/p>\n<h3>4. Fase de arejamento<\/h3>\n<p>Interrompa a inje\u00e7\u00e3o de vapor esterilizante de per\u00f3xido de hidrog\u00e9nio; continue a alimentar o gerador de VHP com um fluxo de ar seco para purificar a tubagem interna do equipamento de VHP. Simultaneamente, ative o exaustor de desinfe\u00e7\u00e3o no sistema de climatiza\u00e7\u00e3o para funcionar num modo de ar totalmente fresco e exaust\u00e3o total. Esta etapa destina-se a reduzir a concentra\u00e7\u00e3o de vapor de per\u00f3xido de hidrog\u00e9nio esterilizante no interior da sala; assim que a concentra\u00e7\u00e3o de g\u00e1s de per\u00f3xido de hidrog\u00e9nio na sala descer abaixo de 1 ppm, termine o processo de aera\u00e7\u00e3o e retome o funcionamento normal do sistema de ar condicionado. Quando necess\u00e1rio, o FGVHP-1000 tamb\u00e9m pode controlar o sistema de ventila\u00e7\u00e3o externo.<\/p>\n<h2 id=\"s4\">IV. Especifica\u00e7\u00f5es t\u00e9cnicas do sistema de esteriliza\u00e7\u00e3o VHP<\/h2>\n<p>O esterilizador Fenggu FGVHP-1000 de Xangai est\u00e1 integrado no sistema de climatiza\u00e7\u00e3o do cliente para a descontamina\u00e7\u00e3o biol\u00f3gica e esteriliza\u00e7\u00e3o de instala\u00e7\u00f5es farmac\u00eauticas est\u00e9reis. O esterilizador est\u00e1 instalado na sala de equipamentos de ar condicionado do cliente e est\u00e1 ligado, atrav\u00e9s de tubagem, ao sistema de condutas da unidade de exaust\u00e3o do ar condicionado. Os principais par\u00e2metros t\u00e9cnicos do sistema de esteriliza\u00e7\u00e3o est\u00e3o indicados na tabela abaixo:<\/p>\n<table>\n<thead>\n<tr>\n<th>N.\u00ba.<\/th>\n<th>Artigo<\/th>\n<th>Unidade<\/th>\n<th>Valor<\/th>\n<th>Observa\u00e7\u00f5es<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Dimens\u00e3o do contorno<\/td>\n<td>mm<\/td>\n<td>1800 (largura) \u00d7 2000 (altura) \u00d7 650 (profundidade)<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Ciclo de esteriliza\u00e7\u00e3o<\/td>\n<td>h<\/td>\n<td>3\u20136<\/td>\n<td>Inclui a dura\u00e7\u00e3o da exala\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Concentra\u00e7\u00e3o de per\u00f3xido de hidrog\u00e9nio para esteriliza\u00e7\u00e3o<\/td>\n<td>ppm<\/td>\n<td>100\u2013800<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Efic\u00e1cia da esteriliza\u00e7\u00e3o<\/td>\n<td>\u2014<\/td>\n<td>Registo n.\u00ba 6<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Concentra\u00e7\u00e3o residual de VHP<\/td>\n<td>ppm<\/td>\n<td>&lt;1,0<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Temperatura de esteriliza\u00e7\u00e3o<\/td>\n<td>\u00b0C<\/td>\n<td>25\u201335<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>Humidade ambiente esterilizada<\/td>\n<td>%<\/td>\n<td>&lt;75<\/td>\n<td>A 25\u201330 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>Volume de esteriliza\u00e7\u00e3o<\/td>\n<td>m\u00b3<\/td>\n<td>0\u20131000<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>Concentra\u00e7\u00e3o de vapor de per\u00f3xido de hidrog\u00e9nio<\/td>\n<td>ppm<\/td>\n<td>0\u2013800<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>Pr\u00e9-desumidifica\u00e7\u00e3o do esterilizador<\/td>\n<td>%<\/td>\n<td>&lt;30<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>11<\/td>\n<td>Capacidade total<\/td>\n<td>KW<\/td>\n<td>15<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>Peso l\u00edquido<\/td>\n<td>Kg<\/td>\n<td>Cerca de 400<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"s5\">V. Lista de configura\u00e7\u00e3o do sistema de esteriliza\u00e7\u00e3o VHP<\/h2>\n<p>O Sistema de Esteriliza\u00e7\u00e3o VHP Fenggu de Xangai \u00e9 composto por um desumidificador rotativo, uma unidade geradora principal, um sistema de distribui\u00e7\u00e3o por tubagem e um sistema de controlo autom\u00e1tico; a configura\u00e7\u00e3o detalhada e as informa\u00e7\u00f5es sobre as marcas constam da tabela abaixo:<\/p>\n<table>\n<thead>\n<tr>\n<th>N.\u00ba.<\/th>\n<th>Produtos e Materiais<\/th>\n<th>Quantidade<\/th>\n<th>Origem \/ Marca<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Desumidificador<\/td>\n<td>1<\/td>\n<td>Su\u00e9cia<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Filtro de part\u00edculas de alta efici\u00eancia<\/td>\n<td>1<\/td>\n<td>Feito \u00e0 medida<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Filtro para solu\u00e7\u00e3o de per\u00f3xido de hidrog\u00e9nio<\/td>\n<td>4<\/td>\n<td>Feito \u00e0 medida<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Controlador PLC<\/td>\n<td>1<\/td>\n<td>Siemens<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Ecr\u00e3 t\u00e1til<\/td>\n<td>1<\/td>\n<td>MCGS<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Computador anfitri\u00e3o remoto<\/td>\n<td>1<\/td>\n<td>Hewlett-Packard<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>Ventilador de alta press\u00e3o<\/td>\n<td>1<\/td>\n<td>AMETEK<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>Evapor\u00edmetro<\/td>\n<td>4<\/td>\n<td>FG<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>Ejetor<\/td>\n<td>4<\/td>\n<td>Shenchen<\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>Transdutor de press\u00e3o diferencial<\/td>\n<td>1<\/td>\n<td>Xinyi<\/td>\n<\/tr>\n<tr>\n<td>11<\/td>\n<td>Sensor de temperatura e humidade<\/td>\n<td>1<\/td>\n<td>Xinyi<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>Sensor de concentra\u00e7\u00e3o<\/td>\n<td>1<\/td>\n<td>ATI<\/td>\n<\/tr>\n<tr>\n<td>13<\/td>\n<td>V\u00e1lvula de esfera el\u00e9trica<\/td>\n<td>1<\/td>\n<td>Kailai<\/td>\n<\/tr>\n<tr>\n<td>14<\/td>\n<td>V\u00e1lvula borboleta el\u00e9trica<\/td>\n<td>2<\/td>\n<td>Kailai<\/td>\n<\/tr>\n<tr>\n<td>15<\/td>\n<td>Bomba de diafragma (enchimento de l\u00edquidos)<\/td>\n<td>2<\/td>\n<td>Shenchen<\/td>\n<\/tr>\n<tr>\n<td>16<\/td>\n<td>Pr\u00e9-aquecedor<\/td>\n<td>4<\/td>\n<td>FG<\/td>\n<\/tr>\n<tr>\n<td>17<\/td>\n<td>Reservat\u00f3rio de fluido<\/td>\n<td>1<\/td>\n<td>FG<\/td>\n<\/tr>\n<tr>\n<td>18<\/td>\n<td>Medidor de conte\u00fado<\/td>\n<td>1<\/td>\n<td>FG<\/td>\n<\/tr>\n<tr>\n<td>19<\/td>\n<td>Luz de aviso<\/td>\n<td>1<\/td>\n<td>Siemens<\/td>\n<\/tr>\n<tr>\n<td>20<\/td>\n<td>Componentes de comuta\u00e7\u00e3o el\u00e9trica<\/td>\n<td>1<\/td>\n<td>Schneider<\/td>\n<\/tr>\n<tr>\n<td>21<\/td>\n<td>Rel\u00e9 el\u00e9trico<\/td>\n<td>V\u00e1rios<\/td>\n<td>Schneider<\/td>\n<\/tr>\n<tr>\n<td>22<\/td>\n<td>Sensor de temperatura<\/td>\n<td>8<\/td>\n<td>Kaixin<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"s6\">VI. Vis\u00e3o geral do sistema de circula\u00e7\u00e3o de condutas<\/h2>\n<h3>Gasoduto VHP<\/h3>\n<ul>\n<li>Fabricado em CPVC, garantindo que o sistema \u00e9 estanque.<\/li>\n<li>A conduta est\u00e1 equipada com medidas de isolamento para evitar a condensa\u00e7\u00e3o do g\u00e1s de per\u00f3xido de hidrog\u00e9nio.<\/li>\n<\/ul>\n<h3>Sistema de condutas de ventila\u00e7\u00e3o<\/h3>\n<ul>\n<li>O sistema de condutas de ventila\u00e7\u00e3o do ar condicionado deve ser estanque; durante a constru\u00e7\u00e3o, a estanqueidade de todas as liga\u00e7\u00f5es das condutas deve ser cuidadosamente inspecionada, uma vez que pode ocorrer qualquer fuga de g\u00e1s de per\u00f3xido de hidrog\u00e9nio.<\/li>\n<li>As v\u00e1lvulas de controlo s\u00e3o instaladas na conduta principal e nas condutas secund\u00e1rias para distribuir per\u00f3xido de hidrog\u00e9nio gasoso.<\/li>\n<\/ul>\n<h2 id=\"s7\">VII. \u00c2mbito do fornecimento<\/h2>\n<h3>\u00c2mbito de fornecimento de Fenggu<\/h3>\n<ul>\n<li>Ficha de Especifica\u00e7\u00f5es de Concep\u00e7\u00e3o (DS);<\/li>\n<li>Unidade principal do gerador VHP, unidade de liga\u00e7\u00e3o ao sistema de condutas de ventila\u00e7\u00e3o e sistema de controlo;<\/li>\n<li>Requisitos dos Servi\u00e7os P\u00fablicos \u2013 Orienta\u00e7\u00f5es de instala\u00e7\u00e3o para condutas de distribui\u00e7\u00e3o de per\u00f3xido de hidrog\u00e9nio;<\/li>\n<li>Sensor para monitoriza\u00e7\u00e3o da concentra\u00e7\u00e3o de VHP nos condutos de ar de retorno do sistema de climatiza\u00e7\u00e3o;<\/li>\n<li>Supervis\u00e3o e orienta\u00e7\u00e3o na instala\u00e7\u00e3o;<\/li>\n<li>Desenvolvimento de processos de esteriliza\u00e7\u00e3o; apoio aos clientes na elabora\u00e7\u00e3o da documenta\u00e7\u00e3o de valida\u00e7\u00e3o; e apoio aos clientes na valida\u00e7\u00e3o de indicadores qu\u00edmicos e biol\u00f3gicos;<\/li>\n<li>Computador anfitri\u00e3o remoto.<\/li>\n<\/ul>\n<h3>\u00c2mbito de trabalho do cliente<\/h3>\n<ul>\n<li>Instala\u00e7\u00e3o e posicionamento do m\u00f3dulo VHP;<\/li>\n<li>Liga\u00e7\u00f5es aos servi\u00e7os p\u00fablicos no local, incluindo o circuito principal de distribui\u00e7\u00e3o de energia e interfaces reservadas para condutas de ar comprimido junto ao equipamento;<\/li>\n<li>Implementa\u00e7\u00e3o da verifica\u00e7\u00e3o;<\/li>\n<li>Os operadores recebem forma\u00e7\u00e3o.<\/li>\n<\/ul>\n<h2 id=\"s8\">VIII. Sistema de ficheiros<\/h2>\n<p>A Shanghai Fenggu conta com uma equipa de t\u00e9cnicos com vasta experi\u00eancia na ind\u00fastria farmac\u00eautica, capaz de ajudar os clientes a estabelecer sistemas de documenta\u00e7\u00e3o que cumpram os requisitos das cGMP; a documenta\u00e7\u00e3o principal a apresentar para o sistema de esteriliza\u00e7\u00e3o VHP est\u00e1 descrita na tabela abaixo:<\/p>\n<table>\n<thead>\n<tr>\n<th>N.\u00ba.<\/th>\n<th>Documento<\/th>\n<th>Abrev.<\/th>\n<th>N.\u00ba do documento.<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>Especifica\u00e7\u00e3o dos Requisitos do Utilizador<\/td>\n<td>URS<\/td>\n<td>2021-002C-00<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Especifica\u00e7\u00f5es do ficheiro<\/td>\n<td>DI<\/td>\n<td>2021-002C-01<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Sistema de controlo de qualidade<\/td>\n<td>QP<\/td>\n<td>2021-002C-02<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Documento de Especifica\u00e7\u00f5es Funcionais<\/td>\n<td>FS<\/td>\n<td>2021-002C-03<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Documento de Especifica\u00e7\u00f5es de Concep\u00e7\u00e3o de Hardware<\/td>\n<td>HDS<\/td>\n<td>2021-002C-04<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Especifica\u00e7\u00e3o de Concep\u00e7\u00e3o de Software<\/td>\n<td>Ficha de Dados de Seguran\u00e7a (FDS)<\/td>\n<td>2021-002C-05<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>An\u00e1lise de risco<\/td>\n<td>RA<\/td>\n<td>2021-002C-06<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>Matriz de rastreabilidade<\/td>\n<td>TM<\/td>\n<td>2021-002C-07<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>Confirma\u00e7\u00e3o do projeto<\/td>\n<td>DQ<\/td>\n<td>2021-002C-08<\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>Confirma\u00e7\u00e3o da instala\u00e7\u00e3o e do funcionamento<\/td>\n<td>IOQ<\/td>\n<td>2021-002C-09<\/td>\n<\/tr>\n<tr>\n<td>11<\/td>\n<td>Confirma\u00e7\u00e3o de desempenho<\/td>\n<td>PQ<\/td>\n<td>2021-002C-10<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>Manual de Instala\u00e7\u00e3o<\/td>\n<td>IM<\/td>\n<td>2021-002C-11<\/td>\n<\/tr>\n<tr>\n<td>13<\/td>\n<td>Manual de utiliza\u00e7\u00e3o<\/td>\n<td>OM<\/td>\n<td>2021-002C-12<\/td>\n<\/tr>\n<tr>\n<td>14<\/td>\n<td>Manual de manuten\u00e7\u00e3o<\/td>\n<td>MM<\/td>\n<td>2021-002C-13<\/td>\n<\/tr>\n<tr>\n<td>15<\/td>\n<td>Testes de aceita\u00e7\u00e3o na f\u00e1brica<\/td>\n<td>FAT<\/td>\n<td>2021-002C-14<\/td>\n<\/tr>\n<tr>\n<td>16<\/td>\n<td>Testes de aceita\u00e7\u00e3o no local do cliente<\/td>\n<td>SAT<\/td>\n<td>2021-002C-15<\/td>\n<\/tr>\n<tr>\n<td>17<\/td>\n<td>Certificado de Conformidade do Produto<\/td>\n<td>CQ<\/td>\n<td>2021-002C-16<\/td>\n<\/tr>\n<tr>\n<td>18<\/td>\n<td>Relat\u00f3rio de Inspe\u00e7\u00e3o Final<\/td>\n<td>FTR<\/td>\n<td>2021-002C-17<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"s9\">IX. Notas importantes<\/h2>\n<ol>\n<li>A Shanghai Fenggu recomenda que o equipamento seja dotado de um circuito de liga\u00e7\u00e3o \u00e0 terra dedicado.<\/li>\n<li>O dispositivo n\u00e3o deve ser utilizado em \u00e1reas onde n\u00e3o seja compat\u00edvel com o VHP.<\/li>\n<li>O sistema de biodecontamina\u00e7\u00e3o deve ser instalado numa superf\u00edcie horizontal r\u00edgida.<\/li>\n<li>Deve ser realizado um teste simulado de esteriliza\u00e7\u00e3o por VHP nas chapas de a\u00e7o revestidas a cores e nas condutas de ar dentro da \u00e1rea da sala limpa.<\/li>\n<li>O sistema de biodecontamina\u00e7\u00e3o FGVHP-1000 deve ser limpo regularmente.<\/li>\n<li>Peso: aproximadamente 380 kg.<\/li>\n<li>O utilizador \u00e9 obrigado a providenciar a verifica\u00e7\u00e3o peri\u00f3dica.<\/li>\n<\/ol>\n<h2 id=\"s10\">X. Anexo: Sistemas de esteriliza\u00e7\u00e3o VHP integrados vs. m\u00f3veis<\/h2>\n<p>O sistema integrado de esteriliza\u00e7\u00e3o VHP oferece as seguintes vantagens em compara\u00e7\u00e3o com os sistemas m\u00f3veis de esteriliza\u00e7\u00e3o com per\u00f3xido de hidrog\u00e9nio:<\/p>\n<figure>\n<img width=\"962\" height=\"723\" decoding=\"async\" src=\"\/wp-content\/uploads\/site\/ksa-vhp-install-2.jpg\" alt=\"Uma unidade integrada FGVHP-1000 que serve v\u00e1rias \u00e1reas est\u00e9reis atrav\u00e9s de uma rede de condutas pr\u00e9-instalada\"><figcaption>Um \u00fanico FGVHP-1000 integrado serve v\u00e1rias \u00e1reas est\u00e9reis atrav\u00e9s de uma rede de condutas pr\u00e9-instalada \u2014 n\u00e3o \u00e9 necess\u00e1rio introduzir nenhuma unidade na zona limpa.<\/figcaption><\/figure>\n<p>Tomando como exemplo uma zona est\u00e9ril de Classe B com 1000 m\u00b3 \u2014 partindo do princ\u00edpio de que esta zona \u00e9 composta por 12 salas \u2014, seriam necess\u00e1rios, pelo menos, tr\u00eas esterilizadores m\u00f3veis de per\u00f3xido de hidrog\u00e9nio (VHP) para concluir o processo de esteriliza\u00e7\u00e3o de toda a \u00e1rea; no entanto, a utiliza\u00e7\u00e3o de um sistema integrado de esteriliza\u00e7\u00e3o por per\u00f3xido de hidrog\u00e9nio exigiria apenas uma \u00fanica unidade FGVHP1000 para realizar a esteriliza\u00e7\u00e3o. Durante o funcionamento, ao contr\u00e1rio dos esterilizadores m\u00f3veis de VHP, o FGVHP1000 n\u00e3o precisa de introduzir cada unidade individualmente na zona est\u00e9ril antes de iniciar a esteriliza\u00e7\u00e3o; em vez disso, o VHP \u00e9 fornecido atrav\u00e9s de sistemas de tubagem pr\u00e9-instalados. O computador central remoto do FGVHP1000 est\u00e1 instalado na sala de controlo do sistema de climatiza\u00e7\u00e3o (HVAC), permitindo que o processo de esteriliza\u00e7\u00e3o seja realizado diretamente a partir desta sala. Atrav\u00e9s da integra\u00e7\u00e3o com a programa\u00e7\u00e3o do sistema de climatiza\u00e7\u00e3o, a sequ\u00eancia de esteriliza\u00e7\u00e3o \u2014 incluindo a prepara\u00e7\u00e3o para a esteriliza\u00e7\u00e3o, a circula\u00e7\u00e3o de VHP e a exaust\u00e3o de VHP \u2014 pode ser executada de forma totalmente autom\u00e1tica; ap\u00f3s a conclus\u00e3o da esteriliza\u00e7\u00e3o, o sistema de climatiza\u00e7\u00e3o regressa automaticamente ao modo de produ\u00e7\u00e3o. Ap\u00f3s a conclus\u00e3o da esteriliza\u00e7\u00e3o, n\u00e3o \u00e9 necess\u00e1rio que o operador vista vestu\u00e1rio esterilizado e entre na zona de Classe B para remover a unidade m\u00f3vel de esteriliza\u00e7\u00e3o com VHP.<\/p>\n<figure>\n<img width=\"964\" height=\"724\" decoding=\"async\" src=\"\/wp-content\/uploads\/site\/vhp-control-room.jpg\" alt=\"Sala de controlo de AVAC com computadores de controlo de AVAC e VHP, permitindo que o processo de esteriliza\u00e7\u00e3o decorra sem necessidade de entrar na \u00e1rea ass\u00e9ptica\"><figcaption>A sala de controlo do sistema de climatiza\u00e7\u00e3o pode realizar opera\u00e7\u00f5es de esteriliza\u00e7\u00e3o por VHP, eliminando a necessidade de os operadores entrarem na \u00e1rea ass\u00e9ptica.<\/figcaption><\/figure>\n<p>Caso sejam necess\u00e1rias v\u00e1rias unidades m\u00f3veis de esteriliza\u00e7\u00e3o por VHP, cada dispositivo deve ser inspecionado quanto ao seu estado operacional e reabastecido com solu\u00e7\u00e3o de per\u00f3xido de hidrog\u00e9nio antes de ser ligado \u2014 um processo que implica custos de m\u00e3o-de-obra significativos, uma vez que se trata de um m\u00e9todo de esteriliza\u00e7\u00e3o manual. Ao utilizar unidades m\u00f3veis de esteriliza\u00e7\u00e3o com VHP, a concentra\u00e7\u00e3o de per\u00f3xido de hidrog\u00e9nio na proximidade destes dispositivos pode tornar-se extremamente elevada durante o processo de esteriliza\u00e7\u00e3o, o que pode corroer facilmente as chapas de a\u00e7o revestidas a cor que se encontram nas imedia\u00e7\u00f5es. No entanto, se for utilizado um sistema integrado de esteriliza\u00e7\u00e3o com per\u00f3xido de hidrog\u00e9nio baseado na climatiza\u00e7\u00e3o, este problema \u00e9 evitado: a inje\u00e7\u00e3o de VHP \u00e9 realizada atrav\u00e9s de condutas de aquecimento e ventila\u00e7\u00e3o, e cada sala est\u00e1 equipada com sa\u00eddas de distribui\u00e7\u00e3o de vapor de per\u00f3xido de hidrog\u00e9nio, eliminando assim o risco de concentra\u00e7\u00e3o excessiva localizada.<\/p>\n<p>O esterilizador m\u00f3vel de VHP funciona com base na esteriliza\u00e7\u00e3o manual; no entanto, as varia\u00e7\u00f5es na disposi\u00e7\u00e3o de cada unidade durante os ciclos de esteriliza\u00e7\u00e3o individuais podem afetar o resultado da esteriliza\u00e7\u00e3o \u2014 uma quest\u00e3o que \u00e9, por natureza, dif\u00edcil de evitar na opera\u00e7\u00e3o manual. A experi\u00eancia pr\u00e1tica demonstrou que a efic\u00e1cia da esteriliza\u00e7\u00e3o dos sistemas m\u00f3veis de esteriliza\u00e7\u00e3o com VHP apresenta uma repetibilidade muito fraca. Em contrapartida, o sistema integrado de esteriliza\u00e7\u00e3o com per\u00f3xido de hidrog\u00e9nio, que distribui a solu\u00e7\u00e3o por cada c\u00e2mara atrav\u00e9s de um conduto centralizado de aquecimento e ventila\u00e7\u00e3o, evita este problema. Durante o processo de esteriliza\u00e7\u00e3o com o sistema integrado de per\u00f3xido de hidrog\u00e9nio, a velocidade do ventilador de alimenta\u00e7\u00e3o do sistema de climatiza\u00e7\u00e3o (HVAC), o volume de ar de alimenta\u00e7\u00e3o e o \u00e2ngulo de abertura\/fecho das v\u00e1lvulas de controlo do volume de ar de alimenta\u00e7\u00e3o e de extra\u00e7\u00e3o s\u00e3o mantidos em valores fixos, o que resulta numa excelente repetibilidade da efic\u00e1cia da esteriliza\u00e7\u00e3o.<\/p>\n<p>O sistema integrado de esteriliza\u00e7\u00e3o com per\u00f3xido de hidrog\u00e9nio \u00e9 altamente escal\u00e1vel; por exemplo, quando oito \u00e1reas est\u00e9reis necessitam de esteriliza\u00e7\u00e3o, pode ser utilizado um \u00fanico sistema integrado de esteriliza\u00e7\u00e3o com per\u00f3xido de hidrog\u00e9nio para esterilizar cada \u00e1rea, distribuindo a solu\u00e7\u00e3o atrav\u00e9s de oito condutas e v\u00e1lvulas separadas. Todas as \u00e1reas est\u00e9reis podem ser esterilizadas automaticamente em sequ\u00eancia, utilizando um programa pr\u00e9-configurado, ou o sistema pode ser configurado antecipadamente para suportar futuras opera\u00e7\u00f5es de esteriliza\u00e7\u00e3o com per\u00f3xido de hidrog\u00e9nio (VHP) em oficinas rec\u00e9m-constru\u00eddas. Consequentemente, essas oficinas n\u00e3o ter\u00e3o de adquirir equipamento adicional de esteriliza\u00e7\u00e3o com VHP \u2013 bastar\u00e1 instalar novas tubagens de esteriliza\u00e7\u00e3o.<\/p>\n<div class=\"fg-cta\">\n<h3>Est\u00e1 a planear um sistema VHP integrado no sistema de climatiza\u00e7\u00e3o para as suas instala\u00e7\u00f5es?<\/h3>\n<p>Envie-nos os volumes das suas \u00e1reas est\u00e9reis e a planta do sistema de climatiza\u00e7\u00e3o \u2014 os nossos engenheiros ir\u00e3o dimensionar um sistema FGVHP e preparar uma solu\u00e7\u00e3o como esta.<\/p>\n<p><a class=\"fg-btn\" href=\"\/pt\/products\/hvac-integrated-vhp-system\/\">Veja o sistema VHP integrado ao sistema de climatiza\u00e7\u00e3o<\/a><br \/>\n<a class=\"fg-btn o\" href=\"\/pt\/contact\/\">Fale com um engenheiro<\/a>\n<\/div>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>Project Case &middot; Saudi Arabia HVAC-Integrated VHP Sterilization System &mdash; Technical Solution By Fenggu Medical Equipment &middot; Pharmaceutical Isolation &amp; [&hellip;]<\/p>\n","protected":false},"author":0,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[4],"tags":[],"class_list":["post-321","post","type-post","status-publish","format-standard","hentry","category-4"],"_links":{"self":[{"href":"https:\/\/fenggu-bio.com\/pt\/wp-json\/wp\/v2\/posts\/321","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fenggu-bio.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fenggu-bio.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/fenggu-bio.com\/pt\/wp-json\/wp\/v2\/comments?post=321"}],"version-history":[{"count":2,"href":"https:\/\/fenggu-bio.com\/pt\/wp-json\/wp\/v2\/posts\/321\/revisions"}],"predecessor-version":[{"id":324,"href":"https:\/\/fenggu-bio.com\/pt\/wp-json\/wp\/v2\/posts\/321\/revisions\/324"}],"wp:attachment":[{"href":"https:\/\/fenggu-bio.com\/pt\/wp-json\/wp\/v2\/media?parent=321"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fenggu-bio.com\/pt\/wp-json\/wp\/v2\/categories?post=321"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fenggu-bio.com\/pt\/wp-json\/wp\/v2\/tags?post=321"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}